• 2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
  • 2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
  • 2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
  • 2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor

2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor

Application: Industrial
Speed: Constant Speed
Number of Stator: Single-Phase
Function: Driving
Casing Protection: Protection Type
Number of Poles: 4
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Recommendation
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
YCL-132SB-4 5.5HP
Starting Mode
y-δ Starting
Certification
ISO9001, CCC, CE
Brand
Liyuan
Housing
Iron-Cast
Cover
Iron-Cast
Terminal Box
PPO
Fan
PP
Fan Cover
A3
Shaft
C45
Transport Package
Carton or Plywood
Trademark
LIYUAN
Origin
Fuan
HS Code
8501400000
Production Capacity
50000 Pieces/Year

Product Description

2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
Recommendation

 

2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
Product Description

2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor

Model hp kw Current Speed Eff Power Factor Tst/Tn Ist/In Tmax/Tn
YCL-132SB-4 5.5 4 22A 1430rpm 84.9% 0.9 2.1 6.5 1.8

2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor
Company Profile

2 Capacitor 220V 230V 240V 5.5 HP Single Phase Electric Motor

FAQ
  1. The danger of motor vibration
     
           The vibration of the motor will shorten the life of the winding insulation and the bearing, and affect the normal lubrication of the sliding bearing. The vibration force promotes the expansion of the insulation gap, allowing external dust and moisture to intrude into it, resulting in a decrease in insulation resistance and an increase in leakage current, and even the formation of insulation breakdown. wait for the accident. In addition, the vibration of the motor will easily crack the water pipe of the cooler, and the welding point will vibrate. At the same time, it will cause damage to the load machine, reduce the accuracy of the workpiece, cause fatigue of all the mechanical parts subjected to vibration, and loosen the anchor screws. Or broken, the motor will cause abnormal wear of the carbon brushes and slip rings, and even serious brush fires will burn the collector ring insulation, and the motor will generate a lot of noise, which generally occurs in DC motors.
    Ten Causes of Motor Vibration
    1. Caused by the imbalance of rotor, coupler, coupling, transmission wheel (brake wheel).
    2. The iron core bracket is loose, the oblique keys and pins are invalid and loose, and the rotor is not tied tightly, which will cause the unbalance of the rotating part.
    3. The shaft system of the linkage part is not centered, the center lines are not coincident, and the centering is incorrect. The cause of this failure is mainly caused by poor alignment and improper installation during the installation process.
    4. The center line of the linkage part is coincident in the cold state, but after running for a period of time, due to the deformation of the rotor fulcrum, the foundation, etc., the center line is damaged again, resulting in vibration.
    5. The gears and couplings connected to the motor are faulty, the gears are poorly meshed, the gear teeth are seriously worn, the lubrication of the wheels is poor, the couplings are skewed and dislocated, the toothed couplings have incorrect tooth shape and pitch, and excessive clearance. Large or serious wear, will cause a certain amount of vibration.
    6. Defects in the structure of the motor itself, the journal is oval, the shaft is bent, the gap between the shaft and the bearing bush is too large or too small, and the rigidity of the bearing seat, foundation plate, part of the foundation and even the entire motor installation foundation is not enough.
    7. Installation problems, the motor and the base plate are not fixed firmly, the foot bolts are loose, the bearing seat and the base plate are loose, etc.
    8. Too large or too small clearance between the shaft and the bearing bush can not only cause vibration, but also cause abnormality in the lubrication and temperature of the bearing bush.
    9. The load driven by the motor conducts vibration, such as the vibration of the fan and water pump driven by the motor, which causes the motor to vibrate.
    10. Wrong connection of AC motor stator, short circuit of rotor winding of wound asynchronous motor, short circuit between turns of excitation winding of synchronous motor, wrong connection of excitation coil of synchronous motor, broken rotor bar of cage type asynchronous motor, and deformation of rotor core, which causes the air gap between stator and rotor to fail. Evenly, the air gap magnetic flux is unbalanced and vibration is caused.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
39
Year of Establishment
2011-07-05