My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor

Product Details
Customization: Available
Application: Industrial
Speed: Constant Speed
Still deciding? Get samples of US$ 1/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
39
Year of Establishment
2011-07-05
  • My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
  • My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
  • My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
  • My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
  • My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
  • My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
Find Similar Products
  • Overview
  • Recommendation
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
MY100L1-4 3HP
Number of Stator
Single-Phase
Function
Driving
Casing Protection
Protection Type
Number of Poles
4
Starting Mode
y-δ Starting
Certification
ISO9001, CCC, CE
Brand
Liyuan
Housing
Aluminum
Cover
Aluminum
Terminal Box
PPO
Fan
PP
Fan Cover
A3
Shaft
C45
Transport Package
Carton or Plywood
Trademark
LIYUAN
Origin
Fuan
HS Code
8501400000
Production Capacity
50000 Pieces/Year

Product Description

My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
Recommendation
My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
 
My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
 
My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
Product Description
My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric MotorMy Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor
Model HP KW Currnet Speed Eff Power Factor Tn Tst/Tn Tmax/Tn
MY-100L-4 3 2.2 12.8A 1440 76% 0.98 14.59 0.28 1.8

My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor

 
Company Profile

My Aluminum Housing Capacitor Run 1725 Rpm 3450 Rpm 3HP 3 HP Single Phase Electric Motor

FAQ
  1. Variable frequency motors are completely different from ordinary motors in two aspects: first, insulation structure; second, ventilation and heat dissipation. The insulation structure is mainly aimed at strengthening the inter-turn insulation of the armature winding for high-frequency shock waves, and the ventilation and heat dissipation structure has many strange shapes due to different motor structures, application occasions and working modes. Here, Ms. refers to the topic of answering and explaining to students, and discusses the ventilation and heat dissipation of motors under the condition of variable frequency power supply. The aforementioned empty shell hood or the fan blades and small motors in the hood are just a few typical structures of the external forced air cooling of the variable frequency motor. They are two types of fans used by the enclosed motor due to the limitation of the size of the motor-ordinary axial flow fans and backpacks. fan.

    According to the structure, the frequency conversion motor can be divided into two categories: closed type and open protection type. The enclosed variable frequency motor with protection level IP44 and above is generally equipped with a forced air cooling fan, and some products with a narrow speed regulation range and a relatively high speed lower limit have their own fans.

    Open the protection type variable frequency motor because the variable frequency motor directly exchanges heat with the surrounding air due to the armature winding, and the lower speed limit is not lower than 50%~70% of the rated speed. Generally, only a little special electromagnetic design can meet the operating conditions. However, the motor with very high power density must also be equipped with a forced air cooling fan, and sand prevention measures should also be taken in the application of the wind and sand environment.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier